The Opus Column Sensor combines a robust die cast aluminium housing, polycarbonate diffuser and marine grade paint finish with an attractive contoured housing ensuring it can be used in arduous applications without compromising aesthetic appeal. These features do not compromise practicality, the Opus Column Sensor incorporates an adjustable spigot allowing for vertical or horizontal mounting adjustable in five degree increments, the control gear department includes an automatic disconnect feature allowing individual luminaires to be serviced without the need to isolate entire circuits and the luminaire is also supplied complete with a ten metre prewired lead for quick and simple connection at the column base. 

The Opus Column Sensor also incorporates our R11 sensor offering presence detection and a wide range of adjustable parameters such as time delays, dimming levels during absence, dimming rates and optional secondary time delays to turn the luminaire off altogether, all programmed via remote control from ground level. An optional NEMA socket allows for integration of a photocell for use for dusk to dawn operation. This versatility is further enhanced with three lens options, open area, wide or asymmetric and lumen outputs ranging from 4,400 up to 25,000 as well as optional integral lithium emergency and wireless control options where central web based control and reporting of luminaires is required. We offer a range of wireless control systems providing localised grouping and control as well as comprehensive wireless solutions allowing both standard and emergency luminaires to be centrally monitored.

OPUS COLUMN SENSOR complies with:

UKCA | CE | IP65 | TM21: L90>80K HOURS | 3 STEP MACADAM ELLIPSE

Recommended applications:

Commercial / Offices | Education | Exterior | Healthcare / Social Housing | Hotel / Leisure | Industrial / Manufacturing | Parking / Exterior | Retail | Transport

Specification

Construction

  • Housing: 0.7mm CR4 steel
  • Housing: High pressure die cast aluminium
  • Finish: Polyester powder painted RAL 9006 matt grey
  • Finish: Polyester powder painted RAL 9005 matt black
  • Finish: Manufactured with a marine grade paint finish to ensure durability in harsh environments.
  • Diffuser: Injection moulded clear polycarbonate
  • Lens: Injection moulded polycarbonate lens
  • IP65

Performance

  • Part L2 compliant
  • 3SDCM Three step Macadams ellipse
  • TM21: L90 at >80,000 Operating Hours
  • Up to 160 luminaire lumens per circuit Watt.
  • Asymmetric lens option allows for optimised spacing’s between columns, also available with Open Area and Wide lenses.
  • Adjustable high light levels allows light output to be adjusted after installation to meet the exact requirements of the installation preventing the need to install multiple luminaire variants and maximising energy savings.

Environmental

  • Designed to allow simple replacement of components with commonly available tools in compliance with the Eco Design Directive, please see the installation leaflet for maintenance instructions.
  • Powered by European branded drivers and emergency modules ensuring replacement parts are easily sourced.
  • Every luminaire is labelled with a unique ID number allowing easy identification of spare parts for the lifetime of the product.
  • Contains no single use plastics or polystyrene packaging.
  • Supplied in plain card boxes with paper tape ensuring packaging is easily recycled.
  • Designed to allow simple disassembly for end of life recycling.
  • UK based manufacturing providing local support throughout the product lifetime and minimising transportation miles.

Emergency

  • Available with optional standard, self test and autotest integral emergency with lithium batteries for extended warranty and lifetime.
  • Optional Reacta-Link wireless emergency for automated centralised reporting.
  • Optional Reacta-Control wireless emergency for automated centralised reporting.

Control

  • Optional Integral R11 presence sensor
  • Optional integral Reacta-Link for integration with Reacta-Link wireless installations
  • Ground level commissioning with REA-AP controller allows quick and simple setting and adjustment of sensors without the need for costly commissioning.

Installation

  • Suitable for column installation, please specify spigot size required.
  • Available with 40-50mm, 50-60mm or 60-76mm spigot
  • Supplied with 10M prewired lead

Variations

  • Available with a wide range of colour temperatures and renderings
  • Available in a range of lumen outputs
  • Available in grey or black finishes
5 year extended warranty available on most products.
Arrow right

OPUS COLUMN SENSOR in action

Technical

Opus Column Sensor

Opus Column Sensor

Opus Column Sensor with Baffle

Opus Column Sensor with Baffle

Ordering

Luminaires

Code Description Power Llm/W
OPUCE L44 OA Opus Column, 3,802llm, Open Area, Colour 74 25.1W 151
OPUCE L60 OA Opus Column, 5,182llm, Open Area, Colour 74 33.8W 153
OPUCE L70 OA Opus Column, 6,046llm, Open Area, Colour 74 41.1W 147
OPUCE L102 OA Opus Column, 8,721llm, Open Area, Colour 74 56.4W 154
OPUCE L133 OA Opus Column, 11,367llm, Open Area, Colour 74 74.6W 152
OPUCE L200 OA Opus Column, 16,540llm, Open Area, Colour 74 114.5W 144
OPUCE L250 OA Opus Column, 20,684llm, Open Area, Colour 74 150.7W 137
OPUCE L44 AS Opus Column, 3,778llm, Asymmetric, Colour 74 25.7W 147
OPUCE L60 AS Opus Column, 5,180llm, Asymmetric, Colour 74 37.9W 137
OPUCE L70 AS Opus Column, 6,043llm, Asymmetric, Colour 74 38.4W 157
OPUCE L102 AS Opus Column, 8,806llm, Asymmetric, Colour 74 57.6W 153
OPUCE L133 AS Opus Column, 11,482llm, Asymmetric, Colour 74 81.1W 141
OPUCE L44 W Opus Column, 3,960llm, Wide, Colour 74 25.1W 157
OPUCE L60 W Opus Column, 5,400llm, Wide, Colour 74 33.8W 160
OPUCE L70 W Opus Column, 6,305llm, Wide, Colour 74 41.1W 153
OPUCE L102 W Opus Column, 9,058llm, Wide, Colour 74 56.4W 160
OPUCE L133 W Opus Column, 11,813llm, Wide, Colour 74 74.6W 158
OPUCE L200 W Opus Column, 17,040llm, Wide, Colour 74 114.5W 148
OPUCE L250 W Opus Column, 21,302llm, Wide, Colour 74 150.7W 141

Control

Code Description
R11 Reacta 11, Presence, IP65, Low Temperature, 3-15M
NEM NEMA Socket
PH Photocell
RLS Reacta-Link Wireless, Presence, 2.5M-5M
RLS10 Reacta-Link Wireless, Presence, 5-10M
RLS15 Reacta-Link Wireless, Presence, 10-15M

Spigot

Code Description
S40 40-50mm Spigot
S50 50-60mm Spigot
S60 60-76mm Spigot
OPUC WB Opus Column Wall Mount Bracket
Please specify spigot size when ordering.
Please order luminaire less spigot when purchasing the wall mount bracket option.

Emergency

Code Description
LE3 Lithium Standard Emergency 3 Hour
LS3 Lithium Selftest Emergency 3 Hour
Emergency luminaires are supplied with a single permanent live connection and must be specified complete with photocell to turn the luminaire off during daylight hours.
Emergency only available in L200 and lower variants.

Miscellaneous

Code Description
C** C727, C73
BL Black Finish
OPUCE BAFFLE REAR GY Opus Column Baffle, Rear, Grey
OPUCE BAFFLE FRONT GY Opus Column Baffle, Front, Grey
OPUCE BAFFLE BOTH GY Opus Column Baffle, Front & Rear, Grey
*  Not available in AS lens L133 and L102